Analyte Specific Reagent. Analytical and performance characteristics are not established.
- Clone
- 9C4
- Other Names
- Ep-CAM, tumor associated calcium signal transducer 1, epithelial cell surface antigen, epithelial glycoprotein 2, EGP2, adenocarcinoma associated antigen, TROP1
- Isotype
- Mouse IgG2b, κ
| Cat # | Size | Price | Quantity Check Availability | Save | ||
|---|---|---|---|---|---|---|
| 989908 | 500 µL | 258€ | ||||
CD326 is also known as Ep-CAM, tumor associated calcium signal transducer 1, epithelial cell surface antigen, epithelial glycoprotein 2, EGP2, adenocarcinoma associated antigen, and TROP1. CD326 is a type I transmembrane protein containing six disulfide bridges and one THYRO domain. This cell surface glycosylated 40 kD protein is highly expressed in bone marrow, colon, lung, and most normal epithelial cells and is expressed on carcinomas of gastrointestinal origin. Recently, it has been reported that CD326 expression occurs during the early steps of erythrogenesis. CD326 functions as a homotypic calcium-independent cell adhesion molecule and is believed to be involved in carcinogenesis by its ability to induce genes involved in cellular metabolism and proliferation.
Product DetailsProduct Details
- Reactivity
- Human
- Formulation
- Phosphate-buffered solution, pH 7.2, 0.09% sodium azide, 0.2% (w/v) BSA (origin USA), and a stabilizer.
- Preparation
- The antibody was purified by affinity chromatography and conjugated with PE under optimal conditions.
- Concentration
- 25 µg/mL
- Storage & Handling
- The antibody solution should be stored undiluted between 2°C and 8°C and protected from prolonged exposure to light. Do not freeze.
- Application
-
Suggested for Flow Cytometry
- Disclaimer
-
WARNINGS AND PRECAUTIONS
- Use appropriate personal protective equipment and safety practices per universal precautions when working with this reagent. Refer to the reagent safety data sheet.
- This antibody contains sodium azide. Follow federal, state and local regulations to dispose of this reagent. Sodium azide build-up in metal wastepipes may lead to explosive conditions; if disposing of reagent down wastepipes, flush with water after disposal.
- All specimens, samples and any material coming in contact with them should be considered potentially infectious and should be disposed of with proper precautions and in accordance with federal, state and local regulations.
- Do not use this reagent beyond the expiration date stated on the label.
- Do not use this reagent if it appears cloudy or if there is any change in the appearance of the reagent as these may be an indication of possible deterioration.
- Avoid prolonged exposure of the reagent or stained cells to light.
Antigen Details
- Antigen References
-
- Strnad J, et al. 1989. Cancer Res. 49:314.
- Munz M, et al. 2004. Oncogene. 23:5748.
- Rao CG, et al. 2005. Int. J. Oncol. 27:49.
Compare Data Across All Formats
This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.
-
Purified anti-human CD326 (EpCAM) (Maxpar® Ready)
Human HT-29 colon carcinoma cells (top) and human Jurkat T c... -
PE/Dazzle™ 594 anti-human CD326 (EpCAM)
Human colon carcinoma cell line HT29 was stained with CD326 ... -
APC/Fire™ 750 anti-human CD326 (EpCAM)
Human colon carcinoma cell line HT29 was stained with CD326 ... -
Brilliant Violet 510™ anti-human CD326 (EpCAM)
Human colon carcinoma cell line HT29 was stained with CD326 ... -
Brilliant Violet 785™ anti-human CD326 (EpCAM)
Human colon carcinoma cell line HT29 was stained with CD326 ... -
Brilliant Violet 711™ anti-human CD326 (EpCAM)
Human colon carcinoma cell line HT29 was stained with CD326 ... -
TotalSeq™-A0123 anti-human CD326 (EpCAM)
-
APC/Cyanine7 anti-human CD326 (EpCAM)
Human colon carcinoma cell line HT29 was stained with CD326 ... -
Alexa Fluor® 700 anti-human CD326 (EpCAM)
Human colon carcinoma cell line HT29 was stained with CD326 ... -
TotalSeq™-C0123 anti-human CD326 (EpCAM)
-
TotalSeq™-B0123 anti-human CD326 (EpCAM)
-
Purified anti-human CD326 (EpCAM)
Human colon carcinoma cell line HT29 stained with purified 9...
BT474 breast cancer cells were stained with anti-human CD326... -
FITC anti-human CD326 (EpCAM)
Human colon carcinoma cell line HT29 stained with 9C4 FITC -
PE anti-human CD326 (EpCAM)
Human colon carcinoma cell line HT29 was stained with CD326 ... -
APC anti-human CD326 (EpCAM)
Human colon carcinoma cell line HT29 stained with 9C4 APC -
Alexa Fluor® 488 anti-human CD326 (EpCAM)
Human colon carcinoma cell line HT29 stained with 9C4 Alexa ...
Confocal image of human jejunum sample acquired using the IB...
Confocal image of human jejunum sample acquired using the IB... -
Alexa Fluor® 647 anti-human CD326 (EpCAM)
Human colon carcinoma cell line (HT29) stainined with 9C4 Al...
MCF7 breast cancer cell line was stained with 4 µg/mL anti-h... -
PerCP/Cyanine5.5 anti-human CD326 (EpCAM)
Human colon carcinoma cell line HT-29 was stained with CD326...
Multiplexed IHC staining of PerCP/Cyanine5.5 anti-CD326 (clo... -
Biotin anti-human CD326 (EpCAM)
Human colon carcinoma cell line (HT29) stained with biotinyl... -
Pacific Blue™ anti-human CD326 (EpCAM)
Human colon carcinoma cell line (HT29) stained with 9C4 Paci... -
Brilliant Violet 421™ anti-human CD326 (EpCAM)
Human colon carcinoma cell line HT29 was stained with 9C4 Br... -
PE/Cyanine7 anti-human CD326 (EpCAM)
HT-29 cells were stained with CD326 (EpCAM) PE/Cyanine7 (fil... -
Brilliant Violet 605™ anti-human CD326 (EpCAM)
Human colon carcinoma cell line HT29 was stained with CD326 ... -
Brilliant Violet 650™ anti-human CD326 (EpCAM)
Human colon carcinoma cell line HT29 was stained with CD326 ... -
Alexa Fluor® 594 anti-human CD326 (EpCAM)
Human paraffin-embedded placenta tissue slices were prepared...
Human colorectal adenocarcinoma cell line HT-29 was fixed wi...
Confocal image of human metastatic lymph node sample acquire... -
PE/Cyanine5 anti-human CD326 (EpCAM)
Human colon carcinoma cell line, HT29 was stained with CD326... -
TotalSeq™-D0123 anti-human CD326 (EpCAM)
-
Spark UV™ 387 anti-human CD326 (EpCAM)
Human colon carcinoma cell line HT29 was stained with anti-h... -
Spark Red™ 718 anti-human CD326 (EpCAM) (Flexi-Fluor™)
-
Spark Blue™ 574 anti-human CD326 (EpCAM) (Flexi-Fluor™)
-
Spark Blue™ 550 anti-human CD326 (Ep-CAM) (Flexi-Fluor™)
-
Brilliant Violet 750™ anti-human CD326 (EpCAM)
Human colon carcinoma cell line HT-29 was stained with anti-... -
Spark PLUS UV395™ anti-human CD326 (Ep-CAM)
Human colon carcinoma cell line HT-29 was stained with anti-... -
PE anti-human CD326
-
Brilliant Violet 570™ anti-human CD326 (Ep-CAM)
HT-29 cells (human colorectal adenocarcinoma cell line) were...
Login / Register 



Follow Us